Skip to content
  • Academy KB Home Redesign
  • Broadband Home
  • CCaaS
  • Channel Partner Support
  • Circle Loop Home
  • Collaborate
  • Connectivity
  • Courses
  • Documentation
  • Ethernet
  • FibreXchange
  • FUSION IoT
  • Gamma AI Concierge
  • Gamma Plus
  • Gamma SIP for Cloud Connect
  • Gamma SIP Global Communications Enablement
  • Gamma SIP Trunks for Genesys Cloud
  • Hannah – Homepage WIP
  • Home
  • Horizon
  • Horizon Contact
  • Horizon Forms
  • Horizon Service Description Home
  • Horizon with Webex
  • Inbound
  • iPECS
  • Knowledge Base Intro
  • Knowledgebase Directory
  • LoginPress
  • Microsoft
  • Microsoft Teams Direct Routing Home
  • Microsoft Teams Operator Connect
  • Mobile
  • Multiple KB
  • My Courses
  • No Access
  • No active page
  • Numbering and Porting
  • Phoneline+
  • Product Homepage
  • Quick Download Button
  • Release Notes
  • Release Notes
  • SIP Home
  • Test
  • UCaaS
  • User Account
  • Voice
  • Voice Enablement
  • Webex for Gamma
  • Webex for Gamma Release Notes
  • Gamma Academy Knowledge Base
Gamma Academy Knowledge Base
  • Cloud Calling and Collaboration
    • Webex for Gamma
    • Horizon with Webex
    • Horizon
    • Phoneline+
    • Operator Connect
    • Direct Routing
    • Inbound
    • Akixi CX Analytics
    • Red Cactus
  • Connectivity and Networking
    • Numbering and Porting
    • Broadband
    • FibreXchange
    • Ethernet
    • SIP Trunking
    • Gamma FUSION IoT
  • CX
    • Horizon Contact
    • AI Concierge
  • Mobile Services
    • Gamma Mobile
  • CyberSecurity
    • SafeWeb
  • Partner & Portal Support
Gamma Academy Knowledge Base

Provisioning and In-Life Changes

  • Before Ordering SIP
    • Gamma Combined Solution Customer Requirement Form
    • Number Requirements
    • Equipment Conformance List
  • Ordering SIP on the Gamma Portal
    • Place a New SIP Order
  • In-Life Configuration
    • Add or Remove Numbers to/from SIP
    • Migrating a Standard Build to Enhanced
    • Fraud Management
    • Call Line Identity (CLI) Rules
    • Change Access Type
    • Update Customer Premises Equipment (CPE)
    • Update IP Address
    • Privacy Settings
    • Codecs & Packetisation
    • Channels
    • Cease an Endpoint
    • Cease Call Manager
  • Service Acceptance Testing
    • Service Acceptance Testing Introduction
    • Stage 1 – SIP Trunking Acceptance Testing
    • Stage 2 – Enhanced Build Testing
    • Stage 3 – Capacity Acceptance (Load test)

Features

  • CLI Flexibility
  • Call Barring
  • Call Diverts

Advanced Features

  • [Legacy] Microsoft Lync / Skype for Business
  • 3cx SIP Configuration
  • SIP Trunk Call Manager Setup
    • Create or Upgrade a New SIP Trunk Call Manager Account
    • Bulk App User Creation
    • Create Users and Profiles
    • End User Call Management Features
  • SIP Trunk Call Manager (STCM) Advanced Features
    • End User Call Management – Additional Features
    • STCM Call Queue Settings & Behaviour
    • STCM Distribution
    • STCM Advanced Statistics & Push Reports
    • STCM Customer Fields
    • STCM Business Continuity
    • STCM Replace Announcements
    • STCM Limit Caller Admissions (LCA)
    • STCM Diverts Guide
    • STCM Setup Notifications for Billable Options
    • STCM Call Plan Validation Errors

Technical Support

  • Diagnosing Faults
    • SIP Health Check
    • Advanced Diagnostics
    • I Have a Problem With Call Quality
    • I Have a Problem With Call Routing Issues
    • Raising a fault
  • Technical Information
    • SIP Infrastructure Upgrade
    • SIP Trunking Infrastructure Upgrade
    • MSX 11&12 IP Address Change Process Guide for Customers
    • PCI Compliance
    • Nuisance and Malicious Calls
    • Hacking
    • DTMF
    • Fax
    • Mass Calling Event
    • Failover on Resilient SIP Designs
  • International Support
    • International SIP FAQ Guide
    • International Equipment Conformance List

Service Description

  • SIP Service Description

T&Cs and SLAs

  • Gamma SIP Trunks Terms and Conditions
  • SIP and Microsoft Teams Phone SLAs
  • SIP Trunks Voice Traffic Policy

SIP SLAs

  • Gamma SIP Trunks – 2025 SLAs
  • Gamma SIP Trunks – 2024 SLAs
  • Gamma SIP Trunks – 2023 SLAs
  • Gamma SIP Trunks – 2022 SLAs
  • Gamma SIP Trunks – 2021 SLAs
  • Gamma SIP Trunks – 2020 SLAs
  • Gamma SIP Trunks – 2019 SLAs
  • Gamma SIP Trunks – 2018 SLAs
  • Gamma SIP Trunks – 2017 SLAs
  • Home
  • Home
  • SIP Trunking
  • Provisioning and In-Life Changes
  • Service Acceptance Testing
  • Stage 3 – Capacity Acceptance (Load test)
View Categories

Stage 3 – Capacity Acceptance (Load test)

It is critical that tests are completed to ensure that both the Ethernet services and SIP elements (customer CPE) are able to support the full solution capacity requirements.

It is the responsibility of the Channel Partner to test the full capability of the CPE, significantly its ability to successfully process the maximum desired number of calls.

Gamma possesses restricted ability to facilitate load testing and it is dependent on CPE function (ability to play back a media stream for a set period of time). We are happy to support this but please note this is a chargeable function and will be assessed on a per project basis.

Charges #

Each agreed load test session is charged at £500.00. A standard solutions order form needs to be completed, signed and returned to Gamma in order to proceed.

Lead time and Outage times #

Gamma requires a 5 working day notice to arrange the load test.

The outage needs to be conducted outside of business hours from 21.30 local time weekdays.

The load test conducted by Gamma is solely to prove: #

That the maximum amount of channels configured for the SIP solution is available and

That the maximum limit of concurrent calls can be reached using the Gamma load testing script and call generator.

Minimum requirement for load testing include: #

Confirmation that you can provide 3 – 5 destination numbers that Gamma can target the concurrent calls to.

On answer of the Gamma calls, your equipment can play back media to a sufficient length of time, detail to be confirmed on conference call with Gamma engineering.

On site equipment must be able to answer and maintain all calls up to the full agreed channel allocation for the agreed call length as this test simulates real world VoIP calls e.g. 300 channels would require 300 answers on site by an IVR or MOH process that will continue to stream media for the agreed amount of time required to reach the full concurrent channel allocation. Gamma will generate calls at the pre-agreed CPS limit up until we reach the channel limit.

 The Gamma software and functionality is limited and we will arrange a 15 minute call about set up, expectations prior to any agreed outage and field any questions or concerns you may have.

The test is to prove that the reseller equipment can handle the amount of channels / concurrent calls enabled to the solution only.

Updated on 10/01/2024
Stage 2 – Enhanced Build TestingService Acceptance Testing Introduction
Contents
  • Charges
  • Lead time and Outage times
  • The load test conducted by Gamma is solely to prove:
  • Minimum requirement for load testing include: